P04 Ultrasonic Detector determines if the parking space is occupied by emitting ultrasonic and analyzing the echo distance from the detector to the reflection surface.
Functions:
- Measure the distance between the detector and the reflection surface.
- Has communication ability.
- Automatic set up the height of the detector.
- Control the arrow displays and symbols to guide.
- Automatic alarm when errors occur.
- May assign address on the spot.
Features:
- Fast and convenient for saving parking time
- Detection to parking spaces effects accurate monitoring.
- Simple structure convenient for installation and maintenance
- Strong ability of anti-interference leads to reliable communications.
- Low power consumption leads to long-lived service.
Technical Parameters |
|
Physical principle |
ultrasonic |
Detection range |
0.5-3.5m |
Max. deviation |
¡À0.1m |
Supply Voltage |
18V DC |
Power |
0.5W |
Dimensions |
115¡Á95¡Á50(mm) |
Working temperature |
-20¡ãC ~70¡ãC |
Communication mode |
RS485 |
Communication rate |
9600bps |
Weight |
0.3kg |
Max. current on the contact of relay |
AC 5A/250V DC 5A/30V |
1. The topology of the connection should be bus mode (commonly known as ¡°hand in hand¡±) instead of star mode ("©×"¡¢"©ï"¡¢"*").
2. The size of the power supply wire should be larger than 1.55mm2 and its color should be different from the RS485 communication wire.
3. The detectors should be mounted at 2.5~3 meters above ground.
4. The detectors must be mounted parallel to the ground.
5. The maximum distance on the bus under a G04P Manager should be no more than 300m and the quantity of the detectors should not be more than 32.
Downwards: it is responsible for communicating with the P04 Ultrasonic Detectors to collect and save the status data.
Upwards: It is responsible for communicating with the data converter to receive various instructions from the controlling software and transmitting the status of the P04 Ultrasonic Detectors.
G04P Manager provides 18V DC power supply for P04 Ultrasonic Detectors. Each G04P Manager is loaded with detectors on a standard of 32. It links P04 Ultrasonic Detectors, displays and other managers with the computer via RS485 communications. The Manager has a LCD display and a keyboard, therefore simple setup is available.

Functions:
- Manage detectors group by group, improve communication loading capacity, assuring the stability of the system communications, maintain conveniently.
- Isolate the optical signals and electrical signals to improve safety and reliability.
- Metal housing with safeguard lock make the ease of installation.
- Built-in residual current operated protective devices
- RS485 communications
Technical Parameters |
|
Supply Voltage |
220V AC |
Output Voltage |
18V DC |
Power consumption |
8W |
Communication mode |
RS485 |
Communication speed |
9600bps |
Communication Distance |
¡Ü1200m |
Dimension |
275¡Á320¡Á130(mm) |
Weight |
6kg |
Descriptions:
- G04P Manager is powered with 220V via RVV3¡Á1.5mm2 wires. Specific circuits are applied for the power supply in order to assure the reliable power.
- 18V power supply is applied for the Manager and detectors through wires of RVV2 X 1.5 mm2.
- The lines for communications between the Manager and data converter as well as detectors are adopted with twisted pairs of RVV X 0.75 mm2 by RS485 communication protocol.
- A G04P Manager is loaded with standard 32 detectors.
G04D Ground Induction Manager could manage at most 6 Ground Induction Detectors. It determines the amount of cars by counting the pulses emitted from the Ground Induction Detector when a car passes by the ground induction coil.
Functions:
- Isolate the optical signals and electrical signals.
- Isolate the optical signals and electrical signals to improve safety and reliability.
- Has RS485 communication function.
Technical Parameters |
|
Supply Voltage |
220VAC |
Power consumption |
8W |
Working temperature |
-10¡ãC~55¡ãC |
Working humidity |
<90% |
Pulse frequency |
<0.5Hz |
Pulse width |
>50ms |
Descriptions:
G04D Ground Induction Manager is powered with 220V, which may detect 6 channels of signals. The input channels of CH1¡«CH6 connect to two normally open terminals of the corresponding grounding induction terminals. The signal output channels GND1 OUT1 and GND6 OUT6 are connected with the signal input terminals of GND1 INI1 and GND6 INI6 of the ground induction manager respectively. There are six indicators corresponding to six signal channels. As soon as the signal output start, the corresponding indicator lights, otherwise, extinguished. Meanwhile, 12V power supply shall be provided for the collector from the isolation panel
Z04 Direction Board
Introduction
Z04 Direction Board is applied for guiding vehicles to appointed unoccupied parking slot, qualified with functions of glint and lasting lighting. In large size parking area, it is necessary for the drivers.
Functions:
- Flash and light for a long period as per instructions from the computer.
Features:
- It applies plug-in in connection, simply in structure and convenient in installation and maintenance.
- It is long in term of use and small in power consumption.
- It is qualified with the function of RS485 communication.
Technical parameters:
Rated working power supply: |
18V AC |
Power: |
0.5w |
Outline dimension: |
350¡Á350mm |
Ambient temperature: |
-20¡ãC ~70¡ãC |
Communication mode: |
RS485 |
Communication speed: |
9600bps |
Weight: |
0.85kg |
Max. Current at relay contact: |
AC 5A/250V DC 5A/30 |
Descriptions:
- The direction board uses 18V DC and adopts wires of RVV2 0.75mm2, of which the power supply is provided by the direction controller.
- The direction controller uses 18V DC and adopts wires of RVV2 1.5mm2, of which the power supply is provided by the manager.
- Twisted pairs of RVVS2 0.75mm2 are adopted for the manager and direction controller as the communication lines and conform to RS485 communication protocol.

Introduction:
LED slot indication board may flash and shine as per the instructions of the system and make the slot clear at a glance for the driver.
Functions:
> Shine and flash as per the instructions delivered by the detectors.
> Help to find out the nearest unoccupied slot for the driver.
Features:
> Plug-in is adopted for connection, simple in structure and convenient in installation and maintenance.
> Long in term of use and small in power consumption.
Technical parameters:
| Power supply: | 18V |
Power consumption: |
5w |
Working temperature: |
-20¡ãC ~70¡ãC |
Outlined dimension: |
350¡Á170mm |
Weight: |
0.55kg |
Information Instruction Display: Please Park at B075 or B077 Slot.
Introduction:
Situated at the entrance of the parking area, it displays the information of welcome and the residual unoccupied slots. Situated in the parking area, it displays the slot information and guides the driver to a instant parking. It displays in standard Chinese and digits with the communication mode of RS232 or RS 485 applied singly or in network.
What display are either the unoccupied slots of the whole parking area or the amount of the residual slots in each district. The status of the unoccupied slots is available through the management system and vehicle detectors and may be reflected on the dynamic slot instruction display. Based on the dynamic slot instruction display, the driver may get to know the amount of the unoccupied slots and how to get to the parking district with unoccupied slots.
Function:
> Different contents are displayed as per the instructions from the computer.
> The content displayed is clear at a glance.
Features:
- Simple in structure and convenient in installation and maintenance.
- Qualified with two communication interfaces of RS485 or RS232.
- Enable to display multi-lines Chinese characters or digits.
- Long in term of use and small in power consumption.
- Reliable in communication and powerful in anti-jamming.
Technical parameters:
Working power supply: |
220V 1 0% |
Ambient temperature: |
-20¡ãC ~65¡ãC |
Relative humidity: |
10%~80% |
Communication distance: |
less than 1000m |
Transmission speed: |
57.6Kbps |
Pixels per character: |
16 1 6 (-Red) |
Dimension of each character: |
122¡Á122mm |
Weight: |
12kg |

Introduction:
The ground induction detector is composed of two parts: ground induction coil and processor. The processor is used to check the vehicles passing by the ground induction coil, collecting induction signals and export corresponding pulse signals. The quantity of the passing vehicles may be judged by different output ports of the pulse signals through setting up different induction sensitivity and working frequency for preventing against mutual interference.
Features parameters:
Power supply |
220V |
Power |
2.5w |
Frequency range |
20-2000Hz |
Sensitivity |
8 levels adjustable |
Response time |
100ms |
Ambient compensation |
Auto floating compensation |
Coil induction |
80-300Uh |
Storage condition |
-40¡ãC ~85¡ãC, |
Outline dimension |
09 4 2 8 0mm |
Working condition |
0¡ãC ~50¡ãC, |
Wire used |
BVR2.0 lead with total resistance |
|
|
AKE reverse searching vehicle system
AKE reverse guiding system is applied for large size parking areas. As the driver forgets where he parked, he may find his car immediately and can be guided to his care along the best route through the AKE system.
Operation process: